Research Article

KPV: Stability-indicating HPLC assay for lysine-proline-valine (KPV) in aqueous solutions and skin homogenates.

A simple, sensitive and stability-indicating high-performance liquid chromatographic (HPLC) assay method was developed and validated for a bioactive peptide, lysine-proline-valine (KPV) in aqueous solutions and skin homogenates. Chromatographic separation was achieved on a reversed phase Phenomenex C18 column (4.6 × 250 mm, packed with 5 µm silica particles) with a gradient mobile phase consisting of 0.1% trifluoroacetic acid (TFA) in water (A) and 0.1% TFA in acetonitrile (B). The proposed HPLC method was validated with respect to accuracy, precision, linearity, repeatability, limit of detection (LOD) and limit of quantitation (LOQ).

Study context

Study design
Preclinical animal study
Population or model
Animal model; verify the species in the source

Research question

What does this source report about KPV, and what evidence model and limitations apply?

Limitations

Confirm the complete study design, intervention identity, population or model, outcomes, statistical context, and limitations in the linked source before approval.

Original source

Stability-indicating HPLC assay for lysine-proline-valine (KPV) in aqueous solutions and skin homogenates.

Kasturi R Pawar, Vanisree Mulabagal, Forrest Smith, Chandra S Kolli, Vijaya K Rangari, R Jayachandra Babu · Biomedical chromatography : BMC · 2016

Source abstract

A simple, sensitive and stability-indicating high-performance liquid chromatographic (HPLC) assay method was developed and validated for a bioactive peptide, lysine-proline-valine (KPV) in aqueous solutions and skin homogenates. Chromatographic separation was achieved on a reversed phase Phenomenex C18 column (4.6 &#xd7; 250 mm, packed with 5 &#xb5;m silica particles) with a gradient mobile phase consisting of 0.1% trifluoroacetic acid (TFA) in water (A) and 0.1% TFA in acetonitrile (B). The proposed HPLC method was validated with respect to accuracy, precision, linearity, repeatability, limit of detection (LOD) and limit of quantitation (LOQ). The calibration curve was linear with a correlation coefficient (r) of 0.9999. Relative standard deviation values of accuracy and precision experiments were <2. The LOD and LOQ of KPV were 0.01 and 0.25 &#xb5;g/mL, respectively. Under stress conditions (acid, alkali and hydrogen peroxide) KPV yielded lys-pro-diketopiperazine as major degradation product, which was identified by flow injection MS analysis. The developed HPLC method was found to be efficient in separating the active peptide from its degradation products generated under various stress conditions. Also, the validated method was able to separate KPV from other peaks arising from endogenous components of the skin homogenate.

Open source record

Related product

Review the complete product page, COAs, specifications, and all approved research sources.

KPV - 10mg research page

This educational summary helps you review the cited source in context. The third-party article is not reproduced, and the citation does not imply endorsement of a related product.